<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Energy Conversion</title>
<title_fa>مهندسی مکانیک تبدیل انرژی</title_fa>
<short_title>تبدیل انرژی</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jeed.dezful.iau.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-9813</journal_id_issn>
<journal_id_issn_online>2008-9813</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1400</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2021</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>8</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی روش های توزیع هوای سیستم سرمایش برای تجهیزات یک مراکز داده</title_fa>
	<title>Investigation of air distribution methods of cooling system for equipments of a data center</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>كاربردي</content_type_fa>
	<content_type>Applicable</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;مراکز داده به اماکنی گفته میشود که سرور ها و تجهیزات &lt;span dir=&quot;LTR&quot;&gt;IT&lt;/span&gt; را در خود جای میدهد. رک در شبکه و&lt;span dir=&quot;LTR&quot;&gt; IT&lt;/span&gt;، سخت افزاری است که ماژول های سخت افزاری مانند سرور، ذخیره ساز &lt;a href=&quot;#_ftn1&quot; name=&quot;_ftnref1&quot; title=&quot;&quot;&gt;&lt;span dir=&quot;LTR&quot;&gt;[1]&lt;/span&gt;&lt;/a&gt;، سوییچ و تجهیزات ارتباطی و &lt;span dir=&quot;LTR&quot;&gt;UPS&lt;/span&gt; و دیگر تجهیزات شبکه را در خود جای می&#8204;دهد. بدین ترتیب در فضایی مناسب و امن، طبقات منسجمی برای نگهداری تجهیزات شبکه را فراهم می&#8204;کند. با توجه به انتشار همیشگی گرما از رک ها مدیریت سیستم های توزیع هوا و سیستم سرمایشی در مراکز داده برای جلوگیری از تخریب بر اثر گرمای زیاد اهمیت ویژه ای دارد. هدف از مدیریت سیستم های توزیع هوا، حل مشکلات موجود در سرمایش مراکز داده، از جمله حداقل نمودن بازگشت هوای گرم، بای پس هوای سرد و حذف نقاط داغ است و همچنین می توان هزینه های زیاد ناشی از سیستم های سرمایش را کاهش و کارآیی آنها را بهبود بخشید.&lt;span dir=&quot;LTR&quot;&gt;&lt;/span&gt;&lt;/div&gt;

&lt;div&gt;&amp;nbsp;
&lt;hr align=&quot;left&quot; size=&quot;1&quot; width=&quot;33%&quot; &gt;
&lt;div id=&quot;ftn1&quot;&gt;&lt;a href=&quot;#_ftnref1&quot; name=&quot;_ftn1&quot; title=&quot;&quot;&gt;&lt;span dir=&quot;LTR&quot;&gt;[1]&lt;/span&gt;&lt;/a&gt; &lt;span dir=&quot;LTR&quot;&gt;Storage&lt;/span&gt;&lt;/div&gt;
&lt;/div&gt;</abstract_fa>
	<abstract>Data centres are enabled by the possibility that servers and its equipments are embedded in the network and it is a hardware that incorporates hardware such as servers , servers , switches , and routers , and other network equipment . Therefore , in a safe and secure space , it will provide you a coherent class to maintain the network equipment due to the constant heat release from the orcs , the management of air distribution systems and the cooling system in data centers to prevent the damage caused by excessive heat . the aim of air distribution systems is to solve the problems in the cooling of the data centers , including minimizing the return of hot air , the cold air and the removal of hot spots . also high cost of cooling systems can be reduced and their efficiency can be improved . index parameters , which include orc cooling index ( rci ) , input and return heat index ( shi ) and return temperature index ( rti ) can play an important role in the performance analysis of air distribution systems . in this research , by numerical modeling of a data center with soft ware , we compare four temperature indexes and performance estimation of subsurface air distribution system . then by changing the current status by proposed methods , the distribution of input and output temperatures to servers are compared and the most suitable ones are proposed</abstract>
	<keyword_fa>مرکز داده, مدیریت توزیع هوا, شبیه سازی عددی, شاخص های دمایی</keyword_fa>
	<keyword>Data center, air distribution management, numerical simulation, temperature indicators</keyword>
	<start_page>48</start_page>
	<end_page>61</end_page>
	<web_url>http://jeed.dezful.iau.ir/browse.php?a_code=A-10-267-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammad</first_name>
	<middle_name></middle_name>
	<last_name>Khodabandeh</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خدابنده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m.khodabandeh@urmia.ac.ir</email>
	<code>10031947532846002904</code>
	<orcid>10031947532846002904</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>University of Urmia, Department of Mechanical Engineering, Urmia</affiliation>
	<affiliation_fa>دانشگاه ارومیه،گروه مهندسی مکانیک، ارومیه</affiliation_fa>
	 </author>


	<author>
	<first_name>Nader</first_name>
	<middle_name></middle_name>
	<last_name>Pourmahmoud</last_name>
	<suffix></suffix>
	<first_name_fa>نادر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پور محمود</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846002905</code>
	<orcid>10031947532846002905</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>University of Urmia, Department of Mechanical Engineering, Urmia</affiliation>
	<affiliation_fa>دانشگاه ارومیه،گروه مهندسی مکانیک، ارومیه</affiliation_fa>
	 </author>


	<author>
	<first_name>Iraj</first_name>
	<middle_name></middle_name>
	<last_name>Mirzaie</last_name>
	<suffix></suffix>
	<first_name_fa>ایرج</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میرزائی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846002906</code>
	<orcid>10031947532846002906</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>University of Urmia, Department of Mechanical Engineering, Urmia</affiliation>
	<affiliation_fa>دانشگاه ارومیه،گروه مهندسی مکانیک، ارومیه</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
