<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Energy Conversion</title>
<title_fa>مهندسی مکانیک تبدیل انرژی</title_fa>
<short_title>تبدیل انرژی</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jeed.dezful.iau.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-9813</journal_id_issn>
<journal_id_issn_online>2008-9813</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>9</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>طراحی تجهیزات سیستم تهویه مطبوع(گرمایش) برای یک ساختمان  5طبقه</title_fa>
	<title>Design of air conditioning (heating) system equipment for a 5-story building</title>
	<subject_fa>سایر (برق، عمران، معماری، هیدرولیک، ماشین آلات کشاورزی، ساخت و تولید، متالوژی، ریاضی، فیزیک، شیمی و ...)</subject_fa>
	<subject>سایر (برق، عمران، معماری، هیدرولیک، ماشین آلات کشاورزی، ساخت و تولید، متالوژی، ریاضی، فیزیک، شیمی و ...)</subject>
	<content_type_fa>كاربردي</content_type_fa>
	<content_type>Applicable</content_type>
	<abstract_fa>&lt;div style=&quot;border-bottom: 1pt solid windowtext; padding: 0cm 0cm 1pt; margin-right: 2px; text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:9pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;در این مقاله به توجه به اطلاعات هواشناسی و داده های بدست آمده از نقشه های هواشناسی بررسی انتخاب تجهیزات و سیستم تهویه مطبوع یک ساختمان 5 طبقه در شهر تهران که&amp;nbsp; با توجه به موقعیت جغرافیایی این ساختمان بار های سرمایش و گرمایشی محاسبه گردیده. محاسبات بار های سرمایشی و گرمایشی هراتاق برای انتخاب رادیاتور هر اتاق صورت گردیده و بخش اول این مقاله محاسبات به صورت دستی صورت گردیده است و بخش دوم با استفاده ار نرم افزار کریر که یک نرم افزار مهم در مبحث تهویه مطبوع می باشد به راستی آزمایی نتایج حاصل از بار های سرمایشی سطحی گردیده است.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;border-bottom: 1pt solid windowtext; padding: 0cm 0cm 1pt; margin-right: 2px; text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:9pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;In this article, according to the meteorological information and the data obtained from the meteorological maps, the selection of equipment and air conditioning system of a 5-story building in the city of Tehran is investigated, and the cooling and heating loads are calculated according to the geographical location of this building. The heating and cooling of the living room has been done to select the radiator for each room and the first part of this article has been calculated manually, and the second part has been used to verify the results of the loads using Carrier software, which is an important software in the field of air conditioning. Surface cooling is done&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:9pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot;B Nazanin&quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>تهویه, بار سرمایش, بار گرمایش, بویلر</keyword_fa>
	<keyword>Ventilation, cooling load, thermal load,boiler</keyword>
	<start_page>29</start_page>
	<end_page>35</end_page>
	<web_url>http://jeed.dezful.iau.ir/browse.php?a_code=A-10-223-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Farzin</first_name>
	<middle_name></middle_name>
	<last_name>Hoseini Fard</last_name>
	<suffix></suffix>
	<first_name_fa>فرزین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسینی فرد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846004138</code>
	<orcid>10031947532846004138</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Qom University, Department of Mechanical Engineering, Qom, Iran</affiliation>
	<affiliation_fa>دانشگاه قم، دانشکده فنی و مهندسی، قم</affiliation_fa>
	 </author>


	<author>
	<first_name>Mostafa</first_name>
	<middle_name></middle_name>
	<last_name>Omidibidgoli</last_name>
	<suffix></suffix>
	<first_name_fa>مصطفی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امیدی بیدگلی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mostafaomidibidgoli@gmail.com</email>
	<code>10031947532846004139</code>
	<orcid>10031947532846004139</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Islamic Azad University Badrood Branch, Department of mechanical engineering, Badrood, Iran</affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی واحد بادرود، گروه مهندسی مکانیک، دانشکده فنی و مهندسی، بادرود</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
