<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Energy Conversion</title>
<title_fa>مهندسی مکانیک تبدیل انرژی</title_fa>
<short_title>تبدیل انرژی</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jeed.dezful.iau.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-9813</journal_id_issn>
<journal_id_issn_online>2008-9813</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2024</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>10</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی جریان هوا و توزیع دمای یک مرکز داده با تراکم حرارتی بالا با استفاده از دینامیک سیالات محاسباتی</title_fa>
	<title>Evaluation of airflow and temperature distribution of a high-density data center using computational fluid dynamics</title>
	<subject_fa>انتقال حرارت و جرم</subject_fa>
	<subject>Heat and Mass Transfer</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;border-bottom:solid windowtext 1.0pt; padding:0in 0in 1.0pt 0in; margin-right:2px&quot;&gt;
&lt;div style=&quot;border-bottom: 1pt solid windowtext; padding: 0in 0in 1pt; margin-right: 2px; text-align: justify;&quot;&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;در مقاله حاضر، با استفاده از دینامیک سیالات محاسباتی الگوی جریان هوا و توزیع دما برای یک مرکز داده با تراکم حرارتی بالا ارائه شده است. مرکز داده توسط نرم&#8204;افزار انسیس ایرپک به &#8204;منظور ارزیابی سیستم خنک&#8204;کاری به&#8204;کاررفته در این مرکز، شبیه&#8204;سازی شده است. سالن مرکز داده در نظر گرفته شده، یک مرکز با تراکم حرارتی نسبتاً بالا است به&#8204;طوری&#8204;که تولید حرارت کلی ایجاد شده در آن برابر 2/227 کیلووات است. چیدمان در نظر گرفته شده برای این مرکز داده به&#8204;صورت پیکربندی راهرو سرد و گرم بوده و دو واحد تهویه&#8204;مطبوع برای تولید هوای سرد در آن تعبیه شده است. در این شبیه&#8204;سازی یک آنالیز سه&#8204;بعدی از جریان هوای سرد&amp;nbsp; و گرم در داخل مرکز داده ارائه شده است و سپس نواحی دما بالا و نواحی برگشت هوای گرم پیش&#8204;بینی شده است. نتایج حاصل از این پژوهش نشان می&#8204;دهد که در قسمت ورودی رک سرورهای با تراکم حرارتی بالاتر، ناحیه&#8204;هایی با دمای 7/32 درجه سلسیوس تشکیل شده است که بالاتر از حد مجاز تعیین شده توسط استاندارد اشری (محدوده دمای بین 18 تا 27 درجه سانتی&#8204;گراد) است. اما توزیع دمای رک سرورهای با تراکم حرارتی پایین&#8204;تر کاملاً منطبق با محدوده دمای مجاز است. همچنین در راهروهای سرد، هوای داغ خروجی در حال چرخش مجدد بوده و با هوای سرد عرضه شده مخلوط می&#8204;شود. مدل ارائه شده در پژوهش حاضر دارای توانایی ارزیابی الگوی جریان هوا، توزیع دما و بارهای حرارتی به&#8204;منظور طراحی مراکز داده جدید و یا بهینه&#8204;سازی مراکز داده موجود به&#8204;منظور کاهش مشکلات موجود در زمینه خنک&#8204;سازی مراکز داده از جمله برگشت هوای گرم و پس&#8204;خوراند هوای سرد است.&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;
&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;border-bottom: 1pt solid windowtext; padding: 0in 0in 1pt; text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;In this paper, using computational fluid dynamics, the air flow pattern and temperature distribution for a high-density data center is presented. The Air-pack software is employed to evaluate the performance of the cooling system within the data center. A high-density data center with a total power density of 227.2 kW is considered. The arrangement considered for the data center is a cold/hot aisle layout and also two computer room air conditioning (CRAC) units are employed to produce cold air flow. A three-dimensional analysis of cold/hot air flow within the data center is provided and high temperature and hot air re-circulation areas are predicted. The results of this research show that in the entrance of the higher thermal density rack servers, there are areas with a temperature of 32.7&lt;sup&gt;0C&lt;/sup&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;, which exceeds the permissible limit determined by the ASHRAE standard. But the temperature distribution of lower thermal density rack servers is completely consistent with the ASHRAE temperature range. Also, the hot exhaust air is recirculating into cold aisles and mixing with the supplied cold air.&amp;nbsp; This model could be used to evaluate the air flow and thermal mapping in order to design a new data centers or to optimize existing data centers in terms of reducing the problems in data center cooling, including hot air return and cold air bypass.&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>سرمایش مرکز داده, دینامیک سیالات محاسباتی, کاهش مصرف انرژی, نواحی دما بالا</keyword_fa>
	<keyword>Data center cooling, Computational fluid dynamics, Energy consumption Reduction, Hot spots</keyword>
	<start_page>59</start_page>
	<end_page>75</end_page>
	<web_url>http://jeed.dezful.iau.ir/browse.php?a_code=A-10-342-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Negin</first_name>
	<middle_name></middle_name>
	<last_name>Moallemi khiavi</last_name>
	<suffix></suffix>
	<first_name_fa>نگین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>معلمی خیاوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846004641</code>
	<orcid>10031947532846004641</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of Mechanical Engineering, Tarbiat Modares University, Tehran , Iran</affiliation>
	<affiliation_fa>دانشگاه تربیت مدرس، دانشکده مهندسی مکانیک، تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Asgar</first_name>
	<middle_name></middle_name>
	<last_name>Minaei</last_name>
	<suffix></suffix>
	<first_name_fa>عسگر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مینایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>a.minaei@uma.ac.ir</email>
	<code>10031947532846004642</code>
	<orcid>10031947532846004642</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Mechanical Engineering, University of Mohaghegh Ardabili, Ardabil, Iran</affiliation>
	<affiliation_fa>دانشگاه محقق اردبیلی، گروه مهندسی مکانیک، دانشکده فنی و مهندسی، اردبیل.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
