<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Energy Conversion</title>
<title_fa>مهندسی مکانیک تبدیل انرژی</title_fa>
<short_title>تبدیل انرژی</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jeed.dezful.iau.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-9813</journal_id_issn>
<journal_id_issn_online>2008-9813</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1403</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2024</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تاثیر برج بادگیر تک کاناله بر جریان هوا و سرمایش ساختمان</title_fa>
	<title>The effect of single-channel wind tower on air flow and cooling of the building</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;line-height: normal;&quot;&gt;&lt;span style=&quot;direction: rtl;&quot;&gt;&lt;span style=&quot;unicode-bidi: embed;&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:;&quot; times=&quot;&quot;&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size: 11pt;&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:;&quot;&gt;در این مقاله با استفاده از روش&#8204;های سنتی و بی&#8204;نیاز از مصرف انرژی در تهویه و خنک&#8204;کاری ساختمان به&#8204;صورت عددی پرداخته شده است. با در نظر گرفتن مدلی از بادگیر به بررسی تاثیر پارامترهای موثر بر روی عملکرد بادگیر مبادرت شده و نتایج حاصل ارائه شده است. دو حالت کلی در نظر گرفته شد که یکی از مدل&#8204;ها شامل یک سطح جاذب حرارت (متناظر با حوض و یا سطوح مرطوب در بادگیرهای سنتی) و دیگری به&#8204;صورت ساده بود. در این تحقیق مشاهده شد که افزایش ارتفاع بادگیر عملکرد آن را بهبود داده و همچنین سرعت باد نیز در کاراریی بادگیر نقش مثبتی دارد. همچنین وجود سطح جاذب حرارت دمای داخل را نسبت به حالت معمولی به مقدار بیشتری کاهش داد. از مدل&#8204;سازی صورت گرفته در این تحقیق مشخص شد که وجود بادگیر می&#8204;تواند تا 11 درجه دمای داخل منزل مسکونی را کاهش داده و همچنین میزان تهویه هوای داخل ساختمان نیز به&#8204;صورت چشمگیری بهبود یابد. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;br&gt;
&amp;nbsp;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;padding: 0in 0in 1pt; text-align: justify; border-bottom-color: windowtext; border-bottom-width: 1pt; border-bottom-style: solid;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:;&quot; times=&quot;&quot;&gt;In this article, using traditional and unnecessary methods, the energy consumption in ventilation and cooling of the building has been numerically analyzed. By considering a model of the wind deflector, the influence of effective parameters on the performance of the wind deflector has been investigated and the results have been presented. Two general cases were considered, one of the models included a heat absorbent surface (corresponding to the pond or wet surfaces in traditional wind deflectors) and the other was simple. In this research, it was observed that increasing the height of the wind deflector has improved its performance and also the wind speed has a positive role in the efficiency of the wind deflector. Also, the presence of a heat absorbing surface reduced the internal temperature to a greater extent than in the normal case. From the modeling carried out in this research, it was found that the presence of wind deflectors can reduce the temperature inside the residential house by 11 degrees and also the amount of air conditioning inside the building can be significantly improved.&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>بادگیر, تهویه مطبوع, سرمایش ساختمان, مطالعه عددی</keyword_fa>
	<keyword>wind deflector, air conditioning, building cooling, numerical study</keyword>
	<start_page>59</start_page>
	<end_page>77</end_page>
	<web_url>http://jeed.dezful.iau.ir/browse.php?a_code=A-10-241-3&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Kouros </first_name>
	<middle_name></middle_name>
	<last_name>Nekoufar</last_name>
	<suffix></suffix>
	<first_name_fa>کورس</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نکوفر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>nekoufar@iauc.ac.ir</email>
	<code>10031947532846005393</code>
	<orcid>10031947532846005393</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Mechanics, Faculty of Technical Engineering, Chalous branch, Islamic Azad University, Chalous, Iran</affiliation>
	<affiliation_fa>گروه مکانیک، دانشکده فنی مهندسی، واحد چالوس، دانشگاه آزاد اسلامی، چالوس، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mehdi </first_name>
	<middle_name></middle_name>
	<last_name>Vadoudi</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ودودی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>vadoudi@gmail.com</email>
	<code>10031947532846005394</code>
	<orcid>10031947532846005394</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of Engineering, Electronic Branch, Islamic Azad University, Iran </affiliation>
	<affiliation_fa>دانشکده فنی مهندسی، واحد الکترونیکی، دانشگاه آزاد اسلامی، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyed Arash </first_name>
	<middle_name></middle_name>
	<last_name>Seyedshams Taleghani</last_name>
	<suffix></suffix>
	<first_name_fa>سیدآرش</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سیدشمس طالقانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>taleghani@ari.ac.ir</email>
	<code>10031947532846005395</code>
	<orcid>10031947532846005395</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Aviation Science and Technology Research Institute, Aerospace Research Institute</affiliation>
	<affiliation_fa>پژوهشکده علوم و فناوری هوایی، پژوهشگاه هوافضا</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
